177
-
NIC Partitioning (*1)
Select whether the NIC Partitioning is used or not.
NIC Partitioning is the feature to use multiple network ports by logically dividing the
network port.
Logical Group Mapping
The boot config can contain settings for the Logical Group Mapping. To provide settings
for the Logical Group Mapping, select [Enable]. The default setting is [Disable].
NOTE:
The features of "Logical Group Mapping" are equivalent to
those of the following switch modules.
GbE Intelligent Switch: "Port Group Mapping" of Smart Panel feature
FC Switch:
"F-N Port Mapping" of Access Gateway
feature
1Gb Interlink Expansion Card
Set this item to [Enable] when installing the 1Gb interlink expansion card in slot #3/#4 of
the switch module. You can access this item only when [Logical Group Mapping] is set to
[Enable]. The default setting is [Disable].
NOTE:
When 1Gb interlink expansion card is installed, ports #3 and
#4 of blade (ports #1 and #2 on Mezzanine slot #1) are connected with
slots #1 and #2 of the switch module.
vIO Control
To use the vIO Control, check to "Enable", and specify "Group ID". The Group ID is an
identifier assigned to a set of vIO configuration which contains virtual MAC address,
virtual WWN, virtual UUID, and virtual product serial number for the single server.
The single server represents one CPU blade, or a set of a CPU blade and I/O blade.
By specifying "Group ID", the unique virtual MAC address, virtual WWN, virtual UUID,
and virtual product serial number are assigned to every port of network card and/or FC
card.
To use the vIO Control feature in two or more blades, the "Group-ID" must be unique in
all the blades.
NOTES:
If [Boot Configuration] is set to "Disable" and [vIO Control] is set
to "Enable", the PXE boot is enabled on onboard LAN port 1.
If you have already changed the parameter of PXE boot on BIOS
SETUP menu, specify the [Boot Configuration] to "Enable", and
specify PXE boot appropriately.
EMFW of this version does not support individual setting of vIO
Control feature.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...