281
-
Execute
Clicking the [Execute] button starts transfer of the update data file between EM cards. Upon
completion of transfer, the firmware of the target EM card is updated.
IMPORTANT:
After updating, the target EM card is rebooted
automatically. If the updating is executed on the active EM card, the
active EM card is switched to another EM card by switchover feature.
NOTES:
The combination of firmware revision available for synchronization
is as follows:
EM card that performs synchronization: Rev 06.00 or later
Another EM card: Rev 02.00 or later
To use this feature, you must be able to connect with both of Web
consoles of Active EM card and Standby EM card.
If you are going to perform revision synchronization on EM card of
which revision is Rev 10.08 or earlier while the other EM card of
which revision is Rev 11.xx or later, the EM cards are not
synchronized to Rev 11.xx or later. In this case, perform
synchronization on Web console of Rev11.xx side.
You cannot undo this operation, therefore, take extreme care to
execute it.
The screen as shown below appears on the EM card to be updated.
NOTE:
The on-screen information is not updated automatically. To
view the latest information, click the [Reload] button.
When update process is completed and the EM card is rebooted, this
screen is no further displayed even though the [Reload] button is
clicked.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...