329
-
KVM Switching
You can change connection of KVM on [Blade Selection Menu].
Select a slot number of the CPU blade to which you want to connect the KVM by using the cursor.
When you press the <Enter> key, the KVM is connected to the selected CPU blade.
When the <Enter> key is pressed, the KVM is disconnected once, and about two seconds later, the
KVM is connected to the selected CPU blade.
During this period, the indication on window disappears. After the KVM is connected, the [Blade
Selection Menu] appears again.
Alternately, you can use one of the keys <1> to <8> while the cursor is placed on any of [Slot1] to
[Slot8] in the KVM field to select a CPU blade to connect the KVM.
IMPORTANT:
If the EM card is not connected correctly or does not operate
normally, the protection feature may work to disable connection of
KVM. When KVM is not available though the correct CPU blade
has been selected, check if the EM card operates normally.
Do not connect or disconnect the KVM while the CPU blade is
being activated. Otherwise, the CPU blade may fail to start.
When the KVM is switched, it may take several seconds until key
entry to the CPU blade becomes valid.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...