Blade Enclosure Inter Connect
If more than one Blade Enclosures are mounted in a single rack, connecting the UPPER port, a
connector on the rear face of a Blade Enclosure, to the LOWER port, a connector on the rear face of
the Blade Enclosure just above, and the LOWER port, another connector on the rear face, to the
UPPER port, a connector on the rear face of the Blade Enclosure just below, through LAN cables
(straight) allows the EM cards to share the rack name and its unique ID among the connected blade
enclosures.
The EM cards can read the status information of the Blade Enclosures and display the information
on Web consoles.
The Rack Information screen on a Web console has the link of each connected Blade Enclosure to
the Web console.
When the same user name and password are set for all the Web consoles, you can automatically log
in to any Web console through the link to the Web console. See Chapter 4 for details of the Web
console.
When rack maximum power consumption management is used (that is, the "Rack Power Limit" is
specified), the Rack Information screen of Web console shows the upper limit of input power for the
overall racks and the upper limit of power consumption allocated for each Blade Enclosure.
Power linkage feature is applied to all over the Blade Enclosures connected with each other.
IMPORTANT:
To use the Blade Enclosure Inter Connect, EM card N8405-019A
must be inserted to any slot.
For the Blade Enclosure Inter Connect, use LAN cables (straight) as
short as possible. LAN cables of three meters or less are
recommended.
Do not connect a LAN cable to the UPPER port of the Blade
Enclosure at the top in a rack and the LOWER port of the Blade
Enclosure at the bottom.
The EM card cannot detect any conflict of vIO information between
the Blade Enclosures. To use the vIO Control feature, vIO
information must be unique.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...