- 358 -
Rebooting the CPU blade after pressing the [Apply] button on Boot Control menu fails to
reflect the configuration to the CPU blade:
Does BIOS of CPU blade or firmware of option card support this feature?
You may need to update the firmware to use this feature.
Refer to the NEC corporate site to get the detailed information for your CPU
blade.
Did you change, add, and/or remove option card?
If you changed, added, and/or removed option card, you must apply [default], and
perform the following steps before applying any boot configurations.
Otherwise, updating boot parameters and/or vIO information by BIOS may fail.
In such a case, perform [Restore Configuration], then perform the following steps
on BIOS SETUP menu.
1. Select [Load Setup Defaults] in Exit menu.
2. Select [Reset Configuration Data] in Advanced menu, and specify [Yes].
3. Press the F10 key to perform [Save and Exit].
Then, apply desired boot configuration again.
Unable to shutdown the OS by UPS Management feature or Power Linkage with NAS Blade
feature:
To shutdown the CPU blade automatically, your OS must be able to shutdown with
the Power button.
Take the following steps to allow your OS to shutdown with the Power button.
Windows Server 2003
Open the Control Panel and open the [Power Options].
Open the [Advanced] tab. From the pull-down menu of [When I press the power
button on my computer] in [Power button], select [Shutdown], and click "OK".
* Validated on Microsoft® Windows Server® 2003 R2 Enterprise (SP1 64-bit).
Windows Server 2008, Windows Server 2008
Open the Control Panel and select [Power Options] - [Choose what the power
button does].
From the pull-down menu of [When I press the power button], select [Shut down],
then click [Save changes].
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...