- 360 -
VMware ESX 4.0
Start the vSphere Client. Select a host machine from the tree at left, and then
double-click [Configuration] in the pane at right.
Select [Virtual Machine Startup/Shutdown].
Click [Properties] at the upper right of the screen.
Put a checkmark on [Allow virtual machines to start and stop automatically with
the system].
On the screen to specify the boot order, move the virtual machine below the item
[Automatic startup].
Click [OK].
With this setting, the host OS can shutdown after the guest OS has shutdown
normally.
* The guest OS must have VMware Tools installed.
* Validated on vSphere Client Version 4.0 and VMware® ESX Version 4.0.
"Reconfiguration failed" or "Reconfiguration skipped" appears on vIO Information List:
Power off the blade server, then reconfigure it according to the following
procedure.
1. Apply [default] of boot config.
2. Power on the blade server, then restart it after the OS has started (or upon
completion of POST if the server has no OS installed).
3. Run BIOS SETUP, select [Load Setup Default], and select [Advanced] - [Reset
Configuration Data]- [Yes]. Then, select [Save and Exit].
4. Shutdown the blade server after the OS has started (or upon completion of
POST if the server has no OS installed).
5. Setup the boot config file again.
If you fail to apply the boot config file configured in Step 5, the blade server or
option card may be faulty.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...