Restoring EM Configuration File
Restores the EM configuration file that has been created by backup procedure from the USB
memory connected to the USB port of the Blade Enclosure.
IMPORTANT:
If you intend to restore the EM configuration file which was backed
up with vIO Control enabled to any other Blade Enclosure, or
relocate the EM card from the Blade Enclosure that are using vIO
Control to any other Blade Enclosure, vIO information may conflict.
To avoid conflict, perform either of the following:
– First make a backup copy of EM configuration file, cancel the
vIO Control of backup source, then restore the EM configuration
file.
– Stop running the restore destination, restore the EM
configuration file, then setup the vIO Control so that settings do
not conflict with those of backup source.
After restoration, be sure to view the Boot Control screen on Web
console. If any blade servers are indicated as "Please (re)boot",
reboot the relevant servers.
Selecting [7: RESTR CONFIG] on [EM CONFIG] menu starts restoration of EM configuration file.
During restoration, the screen as shown below appears.
Restoring CONFIG
The following confirmation screen appears when the configuration file is successfully restored.
Apply?
Y/N
Press [
] or [
] button to move cursor horizontally to switch selection between "Y" and "N".
To apply the restored configuration file, put the cursor on "Y" and press the [Enter] button.
IMPORTANT:
Executing the "apply" command reboots the EM card.
If two EM cards are installed, both cards are rebooted. While rebooting,
a bridge feature and SNMP feature are stopped. Accordingly, the
connection via management LAN of CPU blades and switch module is
temporarily disconnected. In addition, system monitoring by NEC
ESMPRO Manager is temporarily disabled. If a timeout error occurs,
connect them again after the active EM has rebooted.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...