- 88 -
Explanation of output:
Blade Enclosure Inter Connect
Indicates whether the Blade Enclosure Inter Connect is enabled or disabled.
If enabled: ENABLE
If disabled: DISABLE
Detected Blade Enclosures
Indicates the number of Blade Enclosures detected currently.
Blade Enclosure Inter Connect information matching
Indicates whether the Blade Enclosure Inter Connect information saved in every Blade
Enclosure matches the current connect configuration or not.
Matching: MATCH
Other than above: MISMATCH
If "MISMATCH" appears, the following action is required.
–
When the number of detected Blade Enclosures matches the number of Blade
Enclosures connected actually:
The Blade Enclosure Inter Connect information is inconsistent with the current connect
configuration due to a reason such as change of the connect configuration. Update the
Blade Enclosure Inter Connect information. Executing the -e or -d option of this
command allows the Blade Enclosure Inter Connect information to be updated.
–
When the number of detected Blade Enclosures does not match the number of Blade
Enclosures connected actually:
Check the following and issue a command again.
Make sure that all the Blade Enclosures are powered on.
Make sure that the LAN cables (straight) for the Blade Enclosure Inter Connect are
connected appropriately.
Make sure that the EM cards in all the Blade Enclosures can accept the Blade
Enclosure Inter Connect.
When the "-e" option is specified:
Enables the Blade Enclosure Inter Connect. The Blade Enclosure Inter Connect
information in every Blade Enclosure is updated according to the current connect
configuration.
When the "-d" option is specified:
Disables the Blade Enclosure Inter Connect. The Blade Enclosure Inter Connect
information in every Blade Enclosure is updated to "disabled".
It takes several seconds to execute this command. Only active EM cards can execute the
command.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...