191
-
NOTES:
By clicking the [Reset] button, values in this page will be returned
to the value before any changes have been made.
If you set secondary target device, specify the same value as
primary target device for [iSCSI Name] in [Initiator Configuration].
For the devices marked with (*1), the following parameters can be
specified for 2nd Target.
– IP Address in Initiator Configuration
– Subnet Mask in Initiator Configuration
– Gateway in Initiator Configuration
– Primary DNS in Initiator Configuration
– Secondary DNS in Initiator Configuration
– IP Address in Target Configuration (only when MPIO Mode is
set to Disabled)
– TCP Port in Target Configuration (only when MPIO Mode is set
to Disabled)
– iSCSI Name in Target Configuration (only when MPIO Mode is
set to Disabled)
For the other parameters, the same values as primary target device are
used.
NOTES:
For the features marked with (*1), they can be applied to the following
devices.
CPU Blade
CPU Blades listed below does not support this feature:
120Bb-6, 120Bb-m6, 120Bb-d6, 140Ba-10, B140a-T, B120a,
B120a-d, B120b-Lw, B120b, B120b-d, B120b-h
Riser Card
Riser cards listed below support this feature:
N8403-062(F), N8403-063(F), N8403-064(F), N8403-081(F),
N8403-082(F), N8403-083(F)
Option cards for additional slot (I/O card)
Option cards listed below support this feature:
N8403-049(F), N8403-051(F), N8403-065(F), N8403-067(F),
N8403-084(F), N8403-085(F)
Features marked with (*2) has no effect if UEFI is selected for the Boot
Mode.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...