3
-
LED Indication
Shown below are LED indications and their explanations.
STATUS LED
The table below shows the condition of STATUS LED and recommended action.
When a single EM card is installed (in EM card slot EM1 or EM2)
STATUS LED
condition
Meaning
Action
Continuous green
The EM card is working
normally.
–
Flashing in amber
Reset process is in progress.
Wait for a while. When reset process
completes, the LED goes on green.
An error occurred in EM
card.
Replace the EM card according to
Installation/Removal procedure described
later.
When two EM cards are installed (in EM card slots EM1 and EM2)
STATUS LED condition
Meaning
Action
EM card in slot
EM1
EM card in slot
EM2
Continuous green
Flashing in green
The EM card in slot EM1 is
operating as an active card.
The EM card in slot EM2 is
operating as a standby card.
–
Flashing in green
Continuous green
The EM card in slot EM1 is
operating as a standby card.
The EM card in slot EM2 is
operating as an active card.
–
Flashing in amber
Flashing in amber
Reset process is in progress.
Wait for a while. When
reset process
completes, the LED
goes on green.
Flashing in amber
Continuous green
An error occurred on the EM
card in slot EM1.
Replace the failed EM
card according to
installation/removal
procedure.
Continuous green
Flashing in amber
An error occurred on the EM
card in slot EM2.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...