- 14 -
SNMP Agent
SNMP is a protocol used to communicate the management data among network devices.
The administrator of the EM card can use SNMP to monitor the operating status of the EM card and
the blade system (Blade Enclosure, fan units, or power supply units) which the EM card manages.
Registering community name and SNMP trap message destination are to be specified in
configuration file.
NOTES:
SNMP Agent uses "Static IP". For details of Static IP, see "Initial
Setup"
"Basic Setup in Configuration File"
"IP Address of EM
Card".
To monitor the iStorage through EM card, the following registries
must exist in the system in which the NEC ESMPRO Manager is
installed. If not, create them.
----------------------------------------------------------------
[HKEY_LOCAL_MACHINE\SOFTWARE\NEC\NVBASE\AlertView
er\AlertType\iStorage]
"WavDefault"="Server.wav"
"AniDefault"="Default.bmp"
"Image"="Default.bmp"
"SmallImage"="Default.bmp"
----------------------------------------------------------------
The name is placed before "=", and the data is placed after "=".
Data is character-string type.
If your OS is Windows XP (excluding Home Edition), 2000/2003, or
Vista, set the access authority to the alert type key
((~\AlertType\iStorage) as shown below.
Administrators
Full control
Everyone
Read only
SYSTEM
Full control
ESMPRO user group (*)
Full control
(*) ESMPRO user group is specified at installation of NEC ESMPRO
Manager, and represents a group name to control users who use NEC
ESMPRO.
This group name is specified by the user at installation, and it is also
stored in the following registry.
[HKEY_LOCAL_MACHINE\SOFTWARE\NEC\NVBASE]
Name: LocalGroup
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...