57
-
EM Control
Syntax
[RW_EMCTL_SECTION]
CFG_DHCP_ENABLE = <TRUE | FALSE>
CFG_DHCP_BASE_IP = <IP Address>
CFG_DHCP_GATEWAY = <Default Gateway>
CFG_DHCP_NTPSRV = <NTP Server IP>
CFG_PSU_MODE = <PSU mode>
CFG_POWSAVE_MODE = <Powersave mode>
CFG_MAXPOW_SET = <Max Power>
CFG_ACINPUT_WAIT = <Input waiting time>
CFG_SVB_SHUTDOWN_TIMEOUT = <Shutdown time>
CFG_SVB_BOOT_TIMEOUT = <BootTime>
CFG_SVB_SHUTDOWN_TIMEOUT_FOR_BIUPS = <Shutdown time>
CFG_SVB_BOOT_TIMEOUT_FOR_BIUPS = <Boot time>
CFG_DHCP_ENABLE_SLOT_IP = <TRUE | FALSE>
CFG_DHCP_SVB_SLOT1_IP = <Blade1 IP Address>
CFG_DHCP_SVB_SLOT2_IP = <Blade2 IP Address>
CFG_DHCP_SVB_SLOT3_IP = <Blade3 IP Address>
CFG_DHCP_SVB_SLOT4_IP = <Blade4 IP Address>
CFG_DHCP_SVB_SLOT5_IP = <Blade5 IP Address>
CFG_DHCP_SVB_SLOT6_IP = <Blade6 IP Address>
CFG_DHCP_SVB_SLOT7_IP = <Blade7 IP Address>
CFG_DHCP_SVB_SLOT8_IP = <Blade8 IP Address>
CFG_DHCP_SWM_SLOT1_IP = <Switch1 IP Address>
CFG_DHCP_SWM_SLOT2_IP = <Switch2 IP Address>
CFG_DHCP_SWM_SLOT3_IP = <Switch3 IP Address>
CFG_DHCP_SWM_SLOT4_IP = <Switch4 IP Address>
CFG_DHCP_SWM_SLOT5_IP = <Switch5 IP Address>
CFG_DHCP_SWM_SLOT6_IP = <Switch6 IP Address>
CFG_DHCP_UPS1_IP = <UPS1 IP Address>
CFG_DHCP_UPS2_IP = <UPS2 IP Address>
CFG_DHCP_UPS3_IP = <UPS3 IP Address>
CFG_DHCP_UPS4_IP = <UPS4 IP Address>
CFG_NAS_OFF_TIMEOUT_RATIO = <NAS blade off time>
CFG_CPU_ON_TIMEOUT_RATIO = <CPU blade on time>
Description
CFG_DHCP_ENABLE
DHCP server in EM card specifies whether distributing IP addresses to CPU modules and
switch modules are enabled or not.
1: TRUE (enable)
0: FALSE (disable)
The default setting is "1" (enable).
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...