When configuring vIO on B110d, B120d, B120d-h, B120e, B120e-h, B120f, B120f-h, or
B120g-h the system may halt with a POST error message "B000 Expansion ROM not
initialized".
To avoid this error, specify "none" for [Boot Protocol] of the port that is not used for PXE
boot to secure the area for expanding Option ROM.
– [N8403-049(F)] 10GBASE Adapter (4ch)
– [N8403-051(F)] 10GBASE Adapter (4ch) (iSCSI-compliant)
– [N8403-061(F)] 1GBASE Riser Card (2ch)
– [N8403-062(F)] 10GBASE Riser Card (2ch)
– [N8403-064(F)] 10GBASE Riser Card (2ch) (iSCSI-compliant)
– [N8403-065(F)] 10GBASE Adapter (2ch)
– [N8403-067(F)] 10GBASE Adapter (2ch) (iSCSI-compliant)
– [N8403-081(F)] 1GbE (2ch) Riser Card
– [N8403-082(F)] 10GbE (2ch) Riser Card
– [N8403-083(F)] 10GbE (2ch) Riser Card (iSCSI-compliant)
– [N8403-084(F)] 10GBASE Adapter (2ch)
– [N8403-085(F)] 10GBASE Adapter (2ch) (iSCSI-compliant)
– [N8403-094(F)] 1GbE (2ch) Riser Card
– [N8403-095(F)] 10GbE (2ch) Riser Card
– [N8403-096(F)] 10GbE (2ch) Riser Card (iSCSI-compliant)
– [N8403-097(F)] 10GbE (2ch) Adapter
– [N8403-098(F)] 10GbE (2ch) Adapter (iSCSI-compliant)
– [N8403-099(F)] 10GbE (4ch) Adapter
– [N8403-100(F)] 10GbE (4ch) Adapter (iSCSI-compliant)
Refer to the "Setting Procedure for Boot Protocol" document attached to the blade.
Note that the connection between Switch Modules and the ports on N8403-049(F),
N8403-051(F), N8403-099(F), or N8403-100(F) differs when another option card is used.
Virtual MAC Address assigned to each port is determined by the port number regardless
of the type of option card.
Refer to the System Configuration Guide for more information on connection between the
Switch Modules and option card ports.
If you disable NIC Partitioning on devices listed below after applying Boot Config with
vIO Control and NIC Partitioning enabled, remove and reinsert the CPU Blade after
disabling NIC Partitioning.
–
N8403-049(F)
–
N8403-051(F)
–
N8403-062(F)
–
N8403-064(F)
–
N8403-065(F)
–
N8403-067(F)
–
N8403-082(F)
–
N8403-083(F)
–
N8403-084(F)
–
N8403-085(F)
–
N8403-095(F)
–
N8403-096(F)
–
N8403-097(F)
–
N8403-098(F)
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...