- 90 -
initemconfig
Outline
Use this command to initialize the EM card (restore the factory-set values).
Syntax
initemconfig <options>
Parameter
<options>
-y
Explanation:
Initializes the EM card without issuing a message for confirmation.
Details
Use this command to initialize the EM card. Without option switch specified, you are
prompted to select whether to execute or not. Enter "y" to execute initialization.
This command can be executed in the active EM card only.
If two EM cards are installed, the standby EM card is also initialized.
Notes
When applied, the EM firmware is rebooted. If two EM cards are installed, both cards are
rebooted simultaneously.
The bridge and SNMP functions are stopped during rebooting. Accordingly, the CPU
blade and switch module are temporarily disconnected from LAN. In addition, monitoring
the system by NEC ESMPRO or others is temporarily disabled. If a timeout error occurs,
provide these connections again after the active EM has rebooted.
When two EM cards are installed, the standby EM must also be operating normally. If the
standby EM is being activated or failed, the command cannot be executed.
Wait until the standby EM becomes ready, then execute this command.
If the standby EM is failed, remove it. Then, execute this command.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...