363
-
– [N8403-097(F)] 10GbE (2ch) Adapter
– [N8403-098(F)] 10GbE (2ch) Adapter (iSCSI-compliant)
– [N8403-099(F)] 10GbE (4ch) Adapter
– [N8403-100(F)] 10GbE (4ch) Adapter (iSCSI-compliant)
A message "Expansion ROM Not Initialized" appears at the end of POST:
Enabling or disabling Option ROM in manual mode may cause POST error. When
this error message appears, updating boot parameters and/or vIO information by
BIOS may have failed, even if the result status on [Select Boot Configuration]
page is [Success].
Power off the blade server, then perform the following steps.
1. Disable the Option ROM of the device not required for bootup, or execute
[Load Setup Default] of BIOS SETUP.
2. Power off the blade server.
3. Apply [default] of boot config.
4. Setup the boot config file again.
The slot containing a built-in UPS is recognized as it contains the failed power unit:
The built-in UPS may have been recognized incorrectly. Remove the relevant UPS
unit once, then insert it again. If the same error persists, the built-in UPS unit or
midplane may be faulty.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...