![Motortech MIC-Marine Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/motortech/mic-marine/mic-marine_operating-manual_1839332097.webp)
8 Settings via the MICT
Rev. 09/2019
97
8.11.5
Engine – Speed Settings
–
Ignition Release
Enter the release speed for the ignition at which the first ignition is to fire. The value shall
not exceed 1/7 of the nominal speed.
–
Security Speed
Enter the security speed (max. half the nominal speed). Below the value entered, the ignition
can be switched on and off as desired. If the ignition is deactivated during operation above
the set speed, the ignition cannot be immediately reactivated. Only when the ignition no
longer reads a speed, i.e., the engine has come to a standstill, can the ignition be
reactivated.
–
Nominal Speed
Enter the nominal speed at which your engine is to be operated. With engines that are to be
operated with variable speeds, the max. speed of the operating range must be entered.
–
Overspeed
Enter the speed at which the ignition is to be shut off as overspeed protection. With engines
that are to be operated with variable speeds, a speed above the operating range must be
entered.