8 Settings via the MICT
Rev. 09/2019
79
–
Active
The self test is running.
–
Ready
The ignition controller is ready and the self test can be started.
You have the following options:
–
Cycles
Determine whether the self test should run
unlimited
or be terminated after a defined
number of cycles.
–
Outputs
Define whether
all
outputs or only a defined output should be fired during the self test.
–
Cycle Time - All Configured Outputs
Specify the cycle time either as a
period
or
frequency
. The value entered always refers to a
complete cycle. That means that all outputs that are configured are fires once per cycle. If
you only set one output for the self test, this would still only fire once per cycle.
–
Control
Start or stop a self test using the corresponding buttons.
8.8
Pickup Trace
The traces of the pickup signals support you in checking the behavior of the used pickup and
thus, for example, to detect and analyze irregularities or failures.
Pickup signals are automatically recorded by the ignition controller as soon as they are detected
at the configured inputs. Ten further signals are recorded if an error occurs during operation
(cumulative across all inputs). The recording is then stopped so that the pickup signals just
before the error can be analyzed. The records can be downloaded from the device at any time.
Proceed in the MICT as follows:
Device -> Pickup trace
Содержание MIC-Marine
Страница 1: ...MIC6 Ignition Controller Operating Manual P N 01 10 026 EN Rev 09 2019...
Страница 175: ...Rev 09 2019 175...
Страница 176: ......