7 Functions
68
Rev. 09/2019
Application of the ASO signal
The following example will illustrate the application of the ASO signal:
–
Four-stroke engine with 6 cylinders
–
Ignition angle 120° - 120°
Synchronization between MIC6 and Valve Controller
Cyl.
Ignition angle in
°crankshaft
ASO signal in
°crankshaft
Pulse duration in
μs
1
0/720
718
160
2
120
118
80
3
240
238
80
4
360
358
80
5
480
478
80
6
600
598
80
Schematic Representation (Standard Settings)
*
)
active edge
The valve controller should receive the active edge of the ASO signal before
the top dead center of a cylinder. The first pulse duration should be twice
as long and thus mark the beginning of a cycle. The ASO signal generated
by the MIC6 increases by 2° each time before the ignition signal from Low
to High, as can be seen in the schematic drawing. This edge is analyzed by
the valve controller as the active edge.
The ASO signal drops in accordance with the configured pulse duration
from High to Low before the active edge. The valve controller then has
already measured the pulse duration of the active edge and can provide
information on the allocation of the signal. In the example shown here, the
first cylinder is marked with a pulse width of 160 μs versus 80 μs for other
cylinders. If the valve controller measures a pulse width of 160 μs, the
subsequent signal is therefore allocated to the first cylinder. The next
signal then corresponds with the second cylinder in the ignition sequence,
etc.