7 Functions
Rev. 09/2019
69
7.13
Ignition Energy
The ignition energy can be set separately for the start phase and normal operation. Here
different settings can be made for schedules A and B.
You can configure the ignition energy with the MICT. Please refer to the section
Timing –
Schedule A/B – Energy
on page 106.
7.14
Access Control
The MIC6 has four operating levels, three of which can be secured with different PINs. As a
default setting, the access control is not activated. If the access control for the MIC6 is activated,
it is independent from the access levels that control authorizations within the MICT.
Access control in the MICT and on MIC6
A user is logged in to the
Advanced Service
access level on the MICT. He
changes a configuration and would like to download the change to the
MIC6. Although he has the full authorization set in the MICT, he is prompted
to log in with the PIN for the
Level 3 (Master)
on the MIC6.
A variety of functions are at your disposal in the four operating levels of the MIC6 . The figure
below illustrates this: