8 Settings via the MICT
148
Rev. 09/2019
8.14.2
Runtime Adjustments – Timing
The global ignition timing position can be corrected by 50 °crankshaft (advanced/retarded)
while the device is being operated. The correction is made with the buttons:
–
0.1 ADV/RET
in 0.1° increments to advance or retard
–
0.5 ADV/RET
in 0.5° increments to advance or retard
The limit for the ignition timing set in the schedule (refer to
Timing – Schedule A/B – General
on
page 104) cannot be exceeded or not reached with the runtime adjustment.
The correction of the global ignition timing is immediately implemented and also remains in
place if the device is restarted. NOTICE: The configuration defined in the device is not changed.