8 Settings via the MICT
110
Rev. 09/2019
–
Outputs
Activate one or more checkboxes
GPO1, GPO2, GPO3
to enable switching of the
correspondent general purpose output in case the alarm is triggered.
–
GPO Settings
Configure the general purpose outputs as normally closed or normally open.
8.11.13
Inputs/Outputs – ASO1, ASO2 (Auxiliary Synchronization Outputs)
With the auxiliary synchronization outputs, freely definable impulses depending on the angle of
the crankshaft can be generated. For the outputs, the user defines whether the angle will be
absolute or based on the global timing. The outputs can generate between 1 and 24 impulses
and only be assigned to one system at a time. One example of the application of the ASO output
for a detonation controller can be found in section
ASO: Auxiliary Synchronization Outputs
on
–
No. of Points
Select the number of impulses from the
No. of Points
list. Please note that the DetCon
detonation controller devices require a single impulse with 200 μs synchronous with the
first cylinder in the ignition sequence. You can get this setting via the button
Configure for
DetCon2/20
.