7 Functions
66
Rev. 09/2019
7.9
Schedules A/B
The MIC6 ignition controllers offer two separate schedules for the parameterization of the
ignition timing and energy.
By closing input
Schedule A/B
, the listed parameter settings for schedule B can be selected. A
possible application for this is e.g. operation with different gases. If only one schedule is
configured, this is used regardless of the switch position.
You can configure the schedules with the MICT. Refer to
Timing – Schedule A/B – General
on
Timing – Schedule A/B – Energy
on page 106.
Operational safety!
If you use schedules A and B, the advanced timing point should be linked to
schedule B (switch closure). If a wire ruptures, schedule A is automatically
selected with the retarded (and thus safer) timing point.
7.10
Alarms
The MIC6 ignition controllers include 16 freely configurable alarms in total. These alarms can be
freely allocated to the three general purpose outputs (GPO1 to 3) and set depending on the
following functions:
–
Limit for speed exceeded/not reached
–
Limit for engine operating hours exceeded/not reached
–
Limit for spark plug operating hours exceeded/not reached
–
Warning active
–
Error active
–
Limit for temperature exceeded/not reached
–
Limit for supply voltage exceeded/not reached
–
Limit for global ignition timing exceeded/not reached
–
Limit on the analog voltage input exceeded/not reached
–
Limit on the analog current input exceeded/not reached
–
Limit of the minimum spark duration exceeded/not reached
–
Misfire rate (primary, single output) over limit
–
Misfire rate (primary, all outputs) over limit
–
Misfires per second (primary, all outputs) above threshold
–
Consecutive misfires (primary, single output) above threshold
–
Misfire rate (secondary, individual output) above threshold