8.12.7
Runtime Data – Diagnostics
The following information is provided:
–
CAN State
The status display indicates the current error handling status of the device for the CAN bus
communication:
–
Error Active
The device is in normal status of the bus communication. If an error occurs in the
communication, the device sends an active error flag.
–
Error Passive
After a defined number of errors in the bus communication, the device changes to the
status
Error Passive
. If another error occurs, the device sends a passive error flag.