5 Installation Instructions
Rev. 09/2019
33
5.2
Installation of the Ignition Controller
The installation of the MIC6 ignition controller is generally implemented on a fixed bracket e. g.
on a wall near the engine. Use the included vibration dampers and the ground strap. The
following vibration dampers are included in the scope of supply of the respective devices:
–
MIC6
: rubber vibration dampers
–
MIC6-Marine
: wire rope vibration dampers
The installation location of the controller must be selected so that the distance to the pickups
installed on the engine ensures a reliable signal transmission to the ignition controller, and so
that there is adequate space for maintenance and repair work. The mechanical specifications
must always be complied with (refer to
Mechanical Data
on page 20). The ground strap serves to
ground the ignition controller and must be used accordingly. Ensure a flawless electrical
connection for this purpose.
To ensure sufficient cooling through the cooling body, the device must be mounted so that the
vanes of the cooling body are vertical and the hot air can escape upwards unimpeded.
Risk of destruction!
The devices of the MIC6-Marine series may only be installed directly on the
engine with the supplied wire rope vibration dampers. Furthermore the
permissible vibrations and temperatures must not be exceeded because
otherwise electronic components can be destroyed. Refer to the section
Mechanical Data
on page 20.
The MIC6 series devices intended for use with stationary gas engines may
only be installed on the engine if the wire rope vibration dampers intended
for the marine devices are used (not included).