Warning
Description
Incompatible coil parameters
received, secondary voltage
diagnostics disabled.
Incompatible coil parameters received. The secondary
voltage diagnostics have been disabled. This message
may appear during an upgrade/downgrade. Check your
configuration data and the MICT version being used. Then
download the configuration to the device once again.
Invalid coil data received.
Invalid coil data received. This message may appear
during an upgrade/downgrade. Check your configuration
data and the MICT version being used. Then download the
configuration to the device once again.
Pickup configuration invalid.
The pickup configuration is invalid. This message may
appear during an upgrade/downgrade. Check your
configuration data and the MICT version being used. Then
download the configuration to the device once again.
Power output (
x W
) exceeded limit
(
y W
) at a supply voltage of
z V
.
The power output (
x W
) exceeded warning threshold limit
(
y W
) for longer than two minutes at a supply voltage of
z V
.
Speed (
x RPM
) exceeded
overspeed limit (
y RPM
). Previous
speed was
z RPM
.
Speed (
x RPM
) exceeded overspeed limit (
y RPM
).
Previous speed was
z RPM
(see
Engine – Speed Settings
on page 97). The reason for this may also be an
interference coupling on the trigger signal.
Temperature of device (
x °C
)
exceeded limit (
y °C
)
The temperature of the device (
x °C
) exceeded warning
threshold limit (
y °C
) for more than two minutes. Ensure
that there is sufficient air circulation and/or cooling.
8.12.6.3
Alarms
Alarms can be defined in the configuration. When doing so, each alarm is assigned a
number
(see
Inputs/Outputs – Alarms
on page 108).
Alarm
Description
Alarm
number
"
description
"
acknowledged.
The alarm
number
"
description
" was acknowledged.
Alarm
number
"
description
"
triggered.
The alarm
number
"
description
" was triggered.
All alarms reset.
All alarms reset.