7 Functions
64
Rev. 09/2019
Configuration examples
In this example the analog inputs are configured in the
Timing – Analog
Inputs
window as follows:
–
Input current: 4-20 mA
–
Input voltage: 0-5 V
Characteristic 4-20 mA / 0-5 V – Ignition timing adjustment toward
retarded
.
Characteristic 4-20 mA / 0-5 V – Ignition timing adjustment toward
advanced
.
7.5.2
Cylinder-to-Cylinder Alignment
The cylinder-to-cylinder alignment enables the user to change the timing for individual cylinders
to optimize their combustion.
You can enter the settings for the cylinder-to-cylinder alignment with the MICT. Please refer to
the chapter
Cylinder Individual Offsets
on page 152.