7 Functions
Rev. 09/2019
61
7.4
Go/NoGo
The binary output (Go/NoGo) is a potential-free output. It is closed during firing and opens when
the ignition switches off. The max. switching current is 100 mA. The output can drive an external
relay that e.g. opens a gas valve.
The following errors can cause the ignition outputs to shut down:
–
Overspeed
–
Pickup error
–
Error HV power supply
–
Failure of the output monitoring
–
Overload/temperature shut-down
–
Alarms
–
Insufficient supply voltage (Low Power)
Use master control
The outputs of the MIC6 are not SIL compliant. Therefore, always use an
additional master control for safety-critical applications.
7.5
Ignition Timing Adjustment
The ignition controller has several functions for the timing correction.
Influences on ignition timing
Be aware that the actual timing of the engine can also be influenced by
external signals (e.g., analog current or voltage input).
Operational safety!
The MIC6 ignition controller must first be correctly configured for the engine
being used before you can start the engine.
An incorrect configuration can result in damage to the engine.
Содержание MIC-Marine
Страница 1: ...MIC6 Ignition Controller Operating Manual P N 01 10 026 EN Rev 09 2019...
Страница 175: ...Rev 09 2019 175...
Страница 176: ......