9 Operation
164
Rev. 09/2019
Backup the existing configuration
Your device's configuration may be lost if the firmware update is not
performed properly. Always backup the existing configuration via the MICT
prior to performing an update. For more information read the section
Working with Configurations
To start a firmware update, proceed as follows:
1.
If an MICT is connected with the ignition controller, disconnect this connection.
2.
Start the MOTORTECH Flash Tool via
Start -> Programs -> MOTORTECH -> MOTORTECH Flash
Tool -> x.x.x (e.g. 0.9.00003) -> MOTORTECH Flash Tool
.
▸
The MOTORTECH Flash Tool will now start.
▸
The software automatically checks all ports for connected devices.
3.
In the
Status
section under
Device
, check if your device has been recognized properly.
▸
If the MOTORTECH Flash Tool does not recognize a device that is connected to your
computer via the USB interface, you can usually still carry out a firmware update. To do
so, observe the instructions in the information windows of the MOTORTECH Flash Tool
for the following steps.
4.
Select in area
File
using the
Select
button the desired update file.
5.
By reading the displayed file information, ensure that the update file is correct for your
device.
6.
Start the update process using the
Flash
button or using the menu or toolbar.
▸
The ignition controller is restarted automatically.
▸
Now, a window opens informing you about the firmware version currently used on your
ignition controller and also about the relevant update version.
7.
Confirm with
Yes
to proceed with the update process.
▸
Now the update will start.
▸
If the firmware update was successful, you will see a relevant message.
8.
After a successful firmware update, check all configuration data.
Downgrade process
The process for a downgrade is largely the same as the update process. You
will only be informed that a new firmware has been installed on the device.