8 Settings via the MICT
90
Rev. 09/2019
You can use straight order wiring, if:
–
Wiring takes place via a corresponding MOTORTECH wiring harness and a MOTORTECH
wiring rail. The harness is marked with the following information:
PLEASE NOTE! The firing
order needs to be configured directly in the ignition controller.
The ignition coils on the
wiring rail are marked with
Connector Pin 1
to
Connector Pin X
. The position of coil1 on the
wiring rail is marked in the view
Wiring
.
–
Wiring of the ignition controller is done corresponding to the instructions in section
Straight
Order Wiring of the Ignition Outputs
on page 58 (for example with an open wiring harness or
via a junction box).
The configuration of the ignition outputs is automatically adapted corresponding to your
selection. If you want to use a different wiring, these settings must be adapted appropriately.
If the pertinent engine is not available in the database, settings can also be entered by selecting
the corresponding sequence. For this purpose, click on the entry
Sequence
in the column
Engine
Manufacturer
and select the firing stroke in the column
Series
, then the number of cylinders,
and the ignition offset of the engine as needed. After making your selections, the right hand
section
Engine Information
will display a summary of the parameters selected.
The summarized data are transferred to the subsequent configuration page
Ignition Outputs
.
The values displayed there can only be changed by users with authorization to access the
Advanced Service
level.