8 Settings via the MICT
Rev. 09/2019
149
8.14.3
Runtime Adjustments – Energy
The energy settings can be separately adjusted for both schedules. Changes are implemented
immediately and stored in the configuration provided in the device.
Spark Duration
–
+/- 1 μs
lengthen or shorten in microsecond increments
–
+/- 10 μs
lengthen or shorten in 10 μs increments
Spark Intensity
–
+/- 1 mA
increase and decrease in milliampere increments
–
+/- 10 mA
increase or reduce in 10 mA increments