10 Errors
168
Rev. 09/2019
10.2.5
Acknowledging Faults
While the engine is shut down, you have the following options for acknowledging operational
errors:
–
Use
Error Acknowledge
in the MICT
–
Acknowledgment of the error via CAN bus or RS485
–
By disconnecting the supply voltage
–
Hold button
PB
on the controller longer than three seconds
10.3
Troubleshooting
10.3.1
Running a Self Test
You can run the self test via the MICT to check the order of the wiring and the connection
between the ignition controller outputs and the spark plugs. For this refer to section
Self Test
on
Operational safety!
If you carry out a self test, it is essential for the gas supply to be switched
off and no more residual gas is left in the combustion chamber. Non-
compliance can result in damage to equipment or injury to persons.
10.3.2
Customer Service Information
You can reach our customer service during business hours at the following phone and fax
number, or by email:
Phone:
+49 5141 93 99 0
Fax:
+49 5141 93 99 99
Email: [email protected]