8 Settings via the MICT
Rev. 09/2019
107
Normal Operation
If the criteria specified for the start phase are exceeded, the settings for normal operation are
used by the ignition controller. Make the energy settings the same as for the start phase.
Energy Limit
You can use the field
Energy Limit
to limit the output energy made available by the ignition
controller. If the set output energy is no longer sufficient to reach the set energy values (spark
duration, spark intensity, max. breakdown voltage), the spark duration is reduced
correspondingly.
Required supply voltage for energy control
Depending on the output configuration and the energy settings, for a
correct energy control, a higher supply voltage than the minimum 10 V DC
sufficient for operation of the device can be necessary. If this is the case,
the required supply voltage is displayed in a notice in the window
Timing –
Schedule A/B – Energy
.
8.11.11
Timing – Miscellaneous