Status message
Description
Configuration invalid. Using
previous configuration.
The configuration is invalid. The previous configuration is
used. This message may appear during an
upgrade/downgrade. Check your configuration data and
the MICT version being used. Then download the
configuration to the device once again.
Current sensor of output bank
name
failed.
The current sensor of output bank
name
failed. Restart the
ignition controller. If the error occurs again after restarting
the device, please contact MOTORTECH.
Cylinder individual timing
limited to range
timing 1
..
timing 2
The cylinder-individual offset has reached the set limit
(Timing 1
...
Timing 2
(see
Timing – Schedule A/B – General
on page 104).
Device started after supply
voltage failure.
The device was started after a failure of the supply voltage.
Please check the power supply of the device where
applicable.
General error
number
.
General error
number
. Restart the ignition controller. If the
error occurs again after restarting the device, please
contact MOTORTECH.
Global timing
x° crankshaft
limited to range
y° crankshaft
..
z° crankshaft
.
The global timing (
x° crankshaft
) is located outside the
configured limits (
y° crankshaft .. z° crankshaft
; see
Timing
– Schedule A/B – General
on page 104).
Incompatible coil parameters
received, secondary voltage
diagnostics disabled.
Incompatible coil parameters received. The secondary
voltage diagnostics have been disabled. This message may
appear during an upgrade/downgrade. Check your
configuration data and the MICT version being used. Then
download the configuration to the device once again.
Output board identification
failed due to a checksum error.
The identification of the output board failed due to a
checksum error. Restart the ignition controller. If the error
occurs again after restarting the device, please contact
MOTORTECH.
Output board identification
failed due to incompatible
hardware.
The identification of the output board failed due to
incompatible hardware. Restart the ignition controller. If
the error occurs again after restarting the device, please
contact MOTORTECH.
Output board identification
failed due to missing data.
The identification of the output board failed due to missing
data. Restart the ignition controller. If the error occurs
again after restarting the device, please contact
MOTORTECH.