8 Settings via the MICT
Rev. 09/2019
111
–
Angle Reference
Select from the
Angle Reference
drop-down list whether the angle shall be based on the
absolute angle of the crankshaft or the actual angle depending on global timing. Then, enter
the trigger angle for each impulse and the length of the impulse in μs. This setting also
determines when ASO signals are generated. For this, also read the information box
ASO
signals depending on the ignition release
.
–
Mode
Select the mode for the ASO signal.
In the default setting
Trailing Rising Edge (default)
, the signal is low-active.
In the setting
Trailing Falling Edge (inverted)
, the signal is high-active.
* ) active edge marks the configured engine rotation angle
Maximum impulse duration
Please note that the duration of the impulse can be entered as max. 300 μs.
Input of higher values will not be accepted by the system.