7 Functions
Rev. 09/2019
63
7.5.1
Analog Inputs
The timing point control can be adjusted with a linear current signal. This signal can be
supplied, for example, by a potentiometer, a pressure sensor for charging pressure, or a
detonation controller.
With the analog process signal (current loop signal) at the analog current input, the timing point
can be offset in the advanced or retarded direction within a defined range.
Similarly or additionally, the timing can also be influenced by an analog voltage signal at the
corresponding input.
The levels of the analog inputs can be set in the range from 0 mA to 20 mA and 0 V to 10 V. You
can make this configuration with the MICT. Refer to the section
Timing – Analog Inputs
on
At the voltage output (
Analog Power
), a configurable auxiliary voltage is supplied that can be
used for supplying power to external sensors.