8 Settings via the MICT
106
Rev. 09/2019
The first speed point is always set to 0 RPM. All other timing points are assigned with the value
by which the signal is to be offset when the respective speed is reached. For the last speed
point, the timing of the nominal speed should be entered. Please note that the speed points
must always be entered in ascending order.
8.11.10
Timing – Schedule A/B – Energy
You can make different energy settings for the start phase and normal operation.
Start Phase
Set the start phase of your engine. To do this you can enter a
Speed Limit
, a
Time Limit
or both. If
you enter values for both criteria, both values must also be exceeded, so that the ignition
controller classifies the start phase as ended and sets the values for normal operation. If you
only want to use one criterion, set the other value to
0
. If you do not want to define any start-up
phase, set both values to
0
.
Enter values specific to your application for the
Spark Duration
, the
Spark Intensity
and the
Maximum Breakdown Voltage
. The maximum breakdown voltage corresponds to the maximum
voltage expected during operation.