8 Settings via the MICT
108
Rev. 09/2019
You can specify how fast the changes of the timing should be executed.
–
Maximum Firing Angle Change Per Cycle
Specify the maximum degrees per cycle that the ignition timing may be shifted by for both
directions, i.e. between two firings of a cylinder. If the specified ignition timing adjustment
is larger than the given value, it is divided among several cycles.
8.11.12
Inputs/Outputs – Alarms
The MIC6 ignition controllers include a total of 16 configurable alarms that can be allocated to
the general purpose outputs.
–
Description
You can enter any desired description for an alarm. The description is used for logging the
alarms that have occurred in the event list in the MICT.
–
Function
The alarms can be used depending on the following functions:
–
Unused
–
Speed above threshold / below threshold
–
Engine operating hours above threshold / below threshold