8 - 6 8 - 6
MELSEC
8 OPERATING THE UTILITY SOFTWARE
Item Description
5) Error
status
Displays the status of the error currently detected.
Display Description
Normal Normal
status
Transport error
An error was detected in the transmission path.
Parameter error
A parameter error was detected.
CRC error
An error in the received data was detected.
Timeout error
A timeout error was detected in data reception.
Abort error
An error was detected in data communications.
Setting error
An error was detected in the station No./station type setting, the
transmission rate setting or the mode setting.
Illegal
An error arising from some other cause was detected.
6) Board type
Displays the model name of the CC-Link Ver.2 board.
7) Product information
Displays the product information (serial No., function version).
8) IRQ No.
Displays the IRQ No.
9) ROM
version
Displays the ROM version.
10) Memory
Displays the 2-port memory.
11) I/O port
Displays the I/O ports.
12) Present Error
An error code of the error currently identified on the CC-Link Ver.2 board is indicated in
hexadecimal notation.
When no error is currently detected, "No Error" is displayed.
13) Link scan time (ms)
Displays the maximum, minimum and current link scan times.
14) Link refresh time (ms)
Displays the maximum, current and minimum link refresh time of the CC-Link Ver.2 board.
"Block data assurance per Station" indicates "0" when disabled.
15) LED information
Displays the following LED states.
LED Color
ON
OFF
Flashing
RUN Green
Operating
normally.
A WDT error has
occurred, or the board
is being reset.
ERR.
Red
All stations are faulty.
No communication error
has occurred, or the
board is being reset.
There is a faulty
station or station No.
is duplicated.
TIME Red
Due to cable
disconnection or noise
affecting the transmission
path, no responses are
received from all stations.
Responses received
from all stations
MST Green
Operating as the master
station
Operating as other than
the master station
SW
Red
Switch setting error
No switch setting error
LINE
Red
Cable disconnection error
No cable disconnection
error
S MST Green
Operating as a standby
master station
Operating as other than
the standby master
station
M/S
Red
Station duplicated error
Station not duplicated
LOCAL Green
Operating as a local
station
Operating as other than
the local station
PRM
Red
Parameter error
No parameter error
16) OK button
Closes the Board detail information screen.
17) Save SB/SW button
Saves the information of all the CC-Link Ver.2 board SB/SW areas selected on this screen in
CSV format.
Содержание Q80BD-J61BT11N
Страница 2: ......
Страница 34: ...1 10 1 10 MELSEC 1 OVERVIEW MEMO ...
Страница 54: ...3 12 3 12 MELSEC 3 SPECIFICATIONS MEMO ...
Страница 124: ...5 16 5 16 MELSEC 5 PROCEDURE BEFORE STARTING THE DATA LINK MEMO ...
Страница 160: ...9 2 9 2 MELSEC 9 MELSEC DATA LINK LIBRARY MEMO 9 ...
Страница 200: ...12 16 12 16 MELSEC 12 COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL STATIONS MEMO ...
Страница 212: ...13 12 13 12 MELSEC 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATION AJ65BT R2 MEMO ...
Страница 228: ...14 16 14 16 MELSEC 14 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATION AJ65BT D75P2 S3 MEMO ...
Страница 354: ...App 92 App 92 MELSEC APPENDIX Appendix 19 2 Q81BD J61BT11 121 141 147 153 19 158 103 5 91 Unit mm ...
Страница 355: ...App 93 App 93 MELSEC APPENDIX MEMO ...
Страница 361: ......