App - 14 App - 14
MELSEC
APPENDIX
(b) Master station remote I/O station/remote device station/local
station
1) Master station
The output status to the remote I/O station, remote device station
(RY) and all local stations (RX) is stored.
When 1 station is occupied, 2, 4 or 8 words (32, 64 or 128 points)
are used. The number of used points changes depending on the
expanded cyclic setting and the occupied station count. (refer to
Section 3.2)
2) Local station
The data received from the remote I/O station, remote device station
(RY) and master station (RY) is stored.
When 1 station is occupied, 2, 4 or 8 words (32, 64 or 128 points)
are used. The number of used points changes depending on the
expanded cyclic setting and the occupied station count. (refer to
Section 3.2)
X0F to X00
(Example)
Master station
… The last two bits cannot be used for communication between the master
station and the local station.
(In the example below, RYEE and RYEF cannot be used.)
Address
Remote output (RY)
Address
Remote input (RX)
4000
H
4001
H
4002
H
4003
H
4004
H
4005
H
4006
H
4007
H
4008
H
4009
H
41FC
H
41FD
H
41FE
H
41FF
H
400A
H
400B
H
400C
H
400D
H
400E
H
to
RX1FCF to RX1FC0
RX1FDF to RX1FD0
RX1FEF to RX1FE0
RX1FFF to RX1FF0
RX F to RX 0
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX 5F to RX 50
RX 6F to RX 60
RX 7F to RX 70
RX 8F to RX 80
RX 9F to RX 90
RX AF to RX A0
RX BF to RX B0
RX CF to RX C0
RX DF to RX D0
RX ED to RX E0
to
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY 5F to RY 50
RY 6F to RY 60
RY 7F to RY 70
RY 8F to RY 80
RY 9F to RY 90
RY1FCF to RY1FC0
RY1FDF to RY1FD0
RY1FEF to RY1FE0
RY1FFF to RY1FF0
RY AF to RY A0
RY BF to RY B0
RY CF to RY C0
RY DF to RY D0
RY ED to RY E0
to
4200
H
4201
H
4202
H
4203
H
4204
H
4205
H
4206
H
4207
H
4208
H
4209
H
43FC
H
43FD
H
43FE
H
43FF
H
420A
H
420B
H
420C
H
420D
H
420E
H
to
Local station
(Station number 2: Occupies 4 stations,
Expanded cyclic setting: double)
Station
number 1
Station
number 2
Station
number 1
Station
number 2
Remote I/O station
(Station number 1: Occupies 1 station,
Remote I/O station point setting:
16-point setting)
Содержание Q80BD-J61BT11N
Страница 2: ......
Страница 34: ...1 10 1 10 MELSEC 1 OVERVIEW MEMO ...
Страница 54: ...3 12 3 12 MELSEC 3 SPECIFICATIONS MEMO ...
Страница 124: ...5 16 5 16 MELSEC 5 PROCEDURE BEFORE STARTING THE DATA LINK MEMO ...
Страница 160: ...9 2 9 2 MELSEC 9 MELSEC DATA LINK LIBRARY MEMO 9 ...
Страница 200: ...12 16 12 16 MELSEC 12 COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL STATIONS MEMO ...
Страница 212: ...13 12 13 12 MELSEC 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATION AJ65BT R2 MEMO ...
Страница 228: ...14 16 14 16 MELSEC 14 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATION AJ65BT D75P2 S3 MEMO ...
Страница 354: ...App 92 App 92 MELSEC APPENDIX Appendix 19 2 Q81BD J61BT11 121 141 147 153 19 158 103 5 91 Unit mm ...
Страница 355: ...App 93 App 93 MELSEC APPENDIX MEMO ...
Страница 361: ......