3. SIGNALS AND WIRING
3 - 35
(e) Main circuit power supply off during control circuit power supply on
When the main circuit power supply is turned off, all axes will be the operation status below.
POINT
In the torque control mode, the forced stop deceleration function is not available.
CALM (AND malfunction)
MBR
(Electromagnetic
brake interlock)
ON
OFF
ON
OFF
ON (no alarm)
OFF (alarm)
(Note 2)
The time until a voltage
drop is detected.
Main circuit power supply
ON
OFF
Dynamic brake
Forced stop deceleration
Dynamic brake
+ Electromagnetic brake
Electromagnetic brake
Operation delay time of
the electromagnetic brake
Servo motor speed
0 r/min
Approx. 10 ms
(Note 1)
Base circuit
(Energy supply to
the servo motor)
Note 1. ON : Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
2. Variable according to the operation status.
(f) Ready-off command from controller
When ready-off is received, all axes will be the operation status below.
Electromagnetic brake
MBR
(Electromagnetic
brake interlock)
Base circuit
Servo motor speed
Ready-on command
(from controller)
(Note)
ON
OFF
ON
OFF
ON
OFF
Approx. 10 ms
0 r/min
Dynamic brake
Dynamic brake
+ Electromagnetic brake
Operation delay time of
the electromagnetic brake
Note. ON : Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......