APPENDIX
App. - 15
App. 4.6.2 Parts having service lives
Service lives of the following parts are listed below. However, the service lives vary depending on operation
and environment. If any fault is found in the parts, they must be replaced immediately regardless of their
service lives. For parts replacement, please contact your local sales office.
Part name
Life guideline
Smoothing capacitor
(Note 3) 10 years
Relay
Number of power-on,
forced stop and controller forced stop times: 100 000 times
Number of on and off for STO: 1,000,000 times
Cooling fan
10,000 hours to 30,000 hours (2 years to 3 years)
(Note 1) Battery backup time
Approximately 20,000 hours
(equipment power supply: off, ambient temperature: 20 °C)
(Note 2) Battery life
5 years from date of manufacture
Note 1. The time is for using MR-J4 1-axis servo amplifier with an rotary servo motor using MR-BAT6V1SET, MR-BAT6V1SET-A, or
MR-BAT6V1BJ. For details and other battery backup time, refer to chapter 12.
2. Quality of the batteries degrades by the storage condition. The battery life is 5 years from the production date regardless of the
connection status.
3. The characteristic of smoothing capacitor is deteriorated due to ripple currents, etc. The life of the capacitor greatly depends
on ambient temperature and operating conditions. The capacitor will reach the end of its life in 10 years of continuous
operation in normal air-conditioned environment (40 °C surrounding air temperature or less).
App. 4.7 Transportation and storage
CAUTION
Transport the products correctly according to their mass.
Stacking in excess of the limited number of product packages is not allowed.
Do not hold the front cover to transport the servo amplifier. Otherwise, it may
drop.
Install the product in a load-bearing place of servo amplifier and servo motor in
accordance with the Instruction Manual.
Do not get on or put heavy load on the equipment.
For detailed information on the option battery’s transportation and handing refer to
app. 2 and app. 3.
When you keep or use it, please fulfill the following environment.
Item Environment
Ambient
temperature
Operation
[°C]
0 to 55 Class 3K3 (IEC/EN 60721-3-3)
Transportation (Note) [°C]
-20 to 65 Class 2K4 (IEC/EN 60721-3-2)
Storage (Note)
[°C]
-20 to 65 Class 1K4 (IEC/EN 60721-3-1)
Ambient
humidity
Operation, transportation,
storage
5 %RH to 90 %RH
Vibration
resistance
Test condition
10 Hz to 57 Hz with constant amplitude of 0.075 mm
57 Hz to 150 Hz with constant acceleration of 9.8 m/s2 to IEC/EN 61800-5-1
(Test Fc of IEC 60068-2-6)
Operation
5.9
m/s
2
Transportation (Note)
Class 2M3 (IEC/EN 60721-3-2)
Storage
Class 1M2 (IEC/EN 60721-3-2)
Pollution degree
2
IP rating
IP20 (IEC/EN 60529), Terminal block IP00
Open type (UL 50)
Altitude
Operation, storage
Max. 1000 m above sea level
Transportation
Max. 10000 m above sea level
Note. In regular transport packaging
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......