5. PARAMETERS
5 - 23
5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ])
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB01
FILT
Adaptive tuning mode (adaptive filter II)
Set the adaptive filter tuning.
All axes cannot be simultaneously enabled for this function. Set for each axis to use.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Filter tuning mode selection
Select the adjustment mode of the machine resonance
suppression filter 1. Refer to section 7.1.2 for details.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PB02
VRFT
Vibration suppression control tuning mode (advanced vibration suppression control II)
This is used to set the vibration suppression control tuning. Refer to section 7.1.5 for
details.
All axes cannot be simultaneously enabled for this function. Set for each axis to use.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Vibration suppression control 1 tuning mode selection
Select the tuning mode of the vibration suppression control
1.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _
Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression control
2. To enable the digit, select "3 inertia mode (_ _ _ 1)" of
"Vibration suppression mode selection" in [Pr. PA24
Function selection A-4].
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
PB03 TFBGN Torque feedback loop gain
Set a torque feedback loop gain in the continuous operation to torque control mode.
Decreasing the setting value will also decrease a collision load during continuous
operation to torque control mode.
Setting a value less than 6 rad/s will be 6 rad/s.
18000
[rad/s]
0 to
18000
Each
PB04
FFC
Feed forward gain
Set the feed forward gain.
When the setting is 100%, the droop pulses during operation at constant speed are
nearly zero. However, sudden acceleration/deceleration will increase the overshoot.
As a guideline, when the feed forward gain setting is 100%, set 1 s or more as the
acceleration time constant up to the rated speed.
0
[%]
0 to
100
Each
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......