14. USING A LINEAR SERVO MOTOR
14 - 20
(1) Test operation mode type
(a) Positioning operation
Positioning operation can be performed without using the servo system controller. Use this operation
with the forced stop reset. This operation can be used independently of whether the servo is on or
off and whether the servo system controller is connected or not.
Exercise control on the positioning operation screen of MR Configurator2.
1) Operation pattern
Item
Initial value
Setting range
Travel distance [pulse]
1048576
0 to 99999999
Speed [mm/s]
10
0 to Maximum speed
Acceleration/decelerati
on time constant [ms]
1000
0 to 50000
Repeat pattern
Positive direction travel
→
Negative direction travel
Positive direction travel
→
Negative direction travel
Positive direction travel
→
Positive direction travel
Negative direction travel
→
Positive direction travel
Negative direction travel
→
Negative direction travel
Dwell time [s]
2.0
0.1 to 50.0
Number of repeats
[time]
1
1 to 9999
2) Operation method
Operation Screen
control
Positive direction travel
Click the "Positive Direction Movement" button.
Negative direction travel
Click the "Reverse Direction Movement" button.
Pause
Click the "Pause" button.
Stop
Click the "Stop" button.
Forced stop
Click the "Forced stop" button.
(b) Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. This function is
used for output signal wiring check, etc. Exercise control on the DO forced output screen of MR
Configurator2.
(c) Program operation
Positioning operation can be performed in two or more operation patterns combined, without using
the servo system controller. Use this operation with the forced stop reset. This operation may be
used independently of whether the servo is on or off and whether the servo system controller is
connected or not.
Exercise control on the program operation screen of MR Configurator2. For full information, refer to
the MR Configurator2 Installation Guide.
Operation Screen
control
Start
Click the "Operation start" button.
Pause
Click the "Pause" button.
Stop
Click the "Stop" button.
Forced stop
Click the "Forced stop" button.
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......