5. PARAMETERS
5 - 39
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PC09
MOD1
Analog monitor 1 output
Select a signal to output to MO1 (Analog monitor 1). Refer to section 18.3.7 (6) (c) for
detection point of output selection.
The parameter is available with MR-J4W2-0303B6 servo amplifiers.
Refer to the Name
and function
column.
Common
Setting
digit
Explanation
Initial
value
_ _ x x
Analog monitor 1 output selection
Refer to table 5.7 for settings.
00h
_ x _ _
For manufacturer setting
0h
x _ _ _
Analog monitor 1 output axis selection
Select an output axis of Analog monitor 1.
0: A-axis
1: B-axis
0h
Table 5.7 Analog monitor setting value
Setting
value
Item
00
Servo motor speed (10 V ± 4 V/max. speed)
01
Torque (10 V ± 4 V/max. torque)
02
Servo motor speed (10 V + 4 V/max. speed)
03
Torque (10 V + 4 V/max. torque)
04
Current command (10 V ± 4 V/max. current command)
05
Speed command (10 V ± 4 V/max. speed)
06
Servo motor-side droop pulses (10 V ± 5 V/100 pulses) (Note)
07
Servo motor-side droop pulses (10 V ± 5 V/1000 pulses) (Note)
08
Servo motor-side droop pulses (10 V ± 5 V/10000 pulses) (Note)
09
Servo motor-side droop pulses (10 V ± 5 V/100000 pulses) (Note)
0A
Feedback position (10 V ± 5 V/1 Mpulse) (Note)
0B
Feedback position (10 V ± 5 V/10 Mpulses) (Note)
0C
Feedback position (10 V ± 5 V/100 Mpulses) (Note)
0D
Bus voltage (10 V + 5 V/100 V)
0E
Speed command 2 (10 V ± 4 V/max. speed)
17
Encoder inside temperature (10 V ± 5 V/±128 °C)
Note. Encoder pulse unit
PC10
MOD2
Analog monitor 2 output
Select a signal to output to MO2 (Analog monitor 2). Refer to section 18.3.7 (6) (c) for
detection point of output selection.
The parameter is available with MR-J4W2-0303B6 servo amplifiers.
Refer to the Name
and function
column.
Common
Setting
digit
Explanation
Initial
value
_ _ x x
Analog monitor 2 output selection
Refer to [Pr. PC09] for settings.
01h
_ x _ _
For manufacturer setting
0h
x _ _ _
Analog monitor 2 output axis selection
Select an output axis of Analog monitor 2.
0: A-axis
1: B-axis
0h
PC11
MO1
Analog monitor 1 offset
Set the offset voltage of MO1 (Analog monitor 1).
The parameter is available with MR-J4W2-0303B6 servo amplifiers.
0
[mV]
-9999
to
9999
Common
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......