5. PARAMETERS
5 - 27
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB18
LPF
Low-pass filter setting
Set the low-pass filter.
The following shows a relation of a required parameter to this parameter.
3141
[rad/s]
100 to
18000
Each
[Pr. PB23]
[Pr. PB18]
_ _ 0 _ (Initial value)
Automatic setting
_ _ 1 _
Setting value enabled
_ _ 2 _
Setting value disabled
PB19 VRF11 Vibration
suppression
control 1 - Vibration frequency
Set the vibration frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_
_ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
100.0
[Hz]
0.1 to
300.0
Each
PB20 VRF12 Vibration
suppression control 1 - Resonance frequency
Set the resonance frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_
_ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
100.0
[Hz]
0.1 to
300.0
Each
PB21
VRF13 Vibration suppression control 1 - Vibration frequency damping
Set a damping of the vibration frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_
_ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
0.00 0.00
to
0.30
Each
PB22
VRF14 Vibration suppression control 1 - Resonance frequency damping
Set a damping of the resonance frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_
_ _ 1)" in [Pr. PB02], this parameter will be set automatically. Set manually for "Manual
setting (_ _ _ 2)". Refer to section 7.1.5 for details.
0.00 0.00
to
0.30
Each
PB23
VFBF
Low-pass filter selection
Select the shaft resonance suppression filter and low-pass filter.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Shaft resonance suppression filter selection
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine
resonance suppression filter 4 selection" in [Pr. PB49], the
shaft resonance suppression filter is not available.
0h
_ _ x _
Low-pass filter selection
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......