8. TROUBLESHOOTING
8 - 3
No. Name
Detail
No.
Detail name
Stop
System
(Note 2,
3)
Alarm deactivation
Process-
ing
system
Stop
method
Alarm
reset
CPU
reset
Cycling
the
power
Alarm
1A.1 Servo motor combination error 1
DB
Each axis Each axis
1A
Servo motor
combination error
1A.2
Servo motor control mode
combination error
DB
Each axis Each axis
1A.4 Servo motor combination error 2
DB
Each axis Each axis
1E
Encoder initial
communication error 2
1E.1 Encoder
malfunction
DB
Each axis Each axis
1E.2 Load-side encoder malfunction
DB
Each axis Each axis
1F
Encoder initial
communication error 3
1F.1 Incompatible
encoder
DB
Each axis Each axis
1F.2 Incompatible load-side encoder
DB
Each axis Each axis
20.1
Encoder normal communication -
Receive data error 1
EDB
Each axis Each axis
20.2
Encoder normal communication -
Receive data error 2
EDB
Each axis Each axis
20.3
Encoder normal communication -
Receive data error 3
EDB
Each axis Each axis
20
Encoder normal
communication error 1
20.5
Encoder normal communication -
Transmission data error 1
EDB
Each axis Each axis
20.6
Encoder normal communication -
Transmission data error 2
EDB
Each axis Each axis
20.7
Encoder normal communication -
Transmission data error 3
EDB
Each axis Each axis
20.9
Encoder normal communication -
Receive data error 4
EDB
Each axis Each axis
20.A
Encoder normal communication -
Receive data error 5
EDB
Each axis Each axis
21.1 Encoder data error 1
EDB
Each axis Each axis
21.2 Encoder data update error
EDB
Each axis Each axis
Encoder normal
communication error 2
21.3 Encoder data waveform error
EDB
Each axis Each axis
21
21.4 Encoder non-signal error
EDB
Each axis Each axis
21.5 Encoder hardware error 1
EDB
Each axis Each axis
21.6 Encoder hardware error 2
EDB
Each axis Each axis
21.9 Encoder data error 2
EDB
Each axis Each axis
24
Main circuit error
24.1
Ground fault detected at hardware
detection circuit
DB
Each axis All axes
24.2
Ground fault detected by software
detection function
DB
Each axis All axes
25
Absolute position
erased
25.1
Servo motor encoder - Absolute
position erased
DB
Each axis Each axis
25.2
Scale measurement encoder -
Absolute position erased
DB
Each axis Each axis
27
Initial magnetic pole
detection error
27.1
Initial magnetic pole detection -
Abnormal termination
DB
Each axis Each axis
27.2
Initial magnetic pole detection -
Time out error
DB
Each axis Each axis
27.3
Initial magnetic pole detection -
Limit switch error
DB
Each axis Each axis
27.4
Initial magnetic pole detection -
Estimated error
DB
Each axis Each axis
27.5
Initial magnetic pole detection -
Position deviation error
DB
Each axis Each axis
27.6
Initial magnetic pole detection -
Speed deviation error
DB
Each axis Each axis
27.7
Initial magnetic pole detection -
Current error
DB
Each axis Each axis
28
Linear encoder error 2
28.1 Linear encoder - Environment error
EDB
Each axis Each axis
2A.1 Linear encoder error 1-1
EDB
Each axis Each axis
2A.2 Linear encoder error 1-2
EDB
Each axis Each axis
2A.3 Linear encoder error 1-3
EDB
Each axis Each axis
2A
Linear encoder error 1
2A.4 Linear encoder error 1-4
EDB
Each axis Each axis
2A.5 Linear encoder error 1-5
EDB
Each axis Each axis
2A.6 Linear encoder error 1-6
EDB
Each axis Each axis
2A.7 Linear encoder error 1-7
EDB
Each axis Each axis
2A.8 Linear encoder error 1-8
EDB
Each axis Each axis
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...