18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 20
(b) Cable connection procedure
1) Fabrication on cable insulator
Refer to table 18.1 for stripped length of cable insulator. The appropriate stripped length of cables
depends on their type, etc. Set the length considering their fabrication status.
Insulator
Core
Stripped length 10 mm
Twist strands lightly and straighten them as follows.
Loose and bent strands
Twist and straighten
the strands.
You can also use a ferrule to connect with the connectors. When you use a ferrule, use the
following ferrules and crimp terminal.
Wire size
Ferrule model (Phoenix Contact)
Crimping tool
(Phoenix Contact)
For one
For two
AWG 20
AI0.25-10YE
CRIMPFOX6
AWG 18
AI0.34-10TQ
AWG 18
AI0.5-10WH
AWG 16
AI0.75-10GY
2) Inserting wire
When using solid wire, insert the wire to the end. When using stranded wire, insert the wire to the
end with pushing down the release button with a small flat head screwdriver, etc.
The following show a connection example when using stranded wire to the CNP 1 connector.
Release button
Stranded wire
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......