5. PARAMETERS
5 - 16
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PA09
RSP
Auto tuning response
Set a response of the auto tuning.
16
1 to 40 Each
Setting
value
Machine characteristic
Setting
value
Machine characteristic
Response
Guideline for
machine
resonance
frequency [Hz]
Response
Guideline for
machine
resonance
frequency [Hz]
1
Low
response
Middle
response
2.7
21
Middle
response
High
response
67.1
2
3.6
22
75.6
3
4.9
23
85.2
4
6.6
24
95.9
5
10.0
25
108.0
6
11.3
26
121.7
7
12.7
27
137.1
8
14.3
28
154.4
9
16.1
29
173.9
10
18.1
30
195.9
11
20.4
31
220.6
12
23.0
32
248.5
13
25.9
33
279.9
14
29.2
34
315.3
15
32.9
35
355.1
16
37.0
36
400.0
17
41.7
37
446.6
18
47.0
38
501.2
19
52.9
39
571.5
20
59.6
40
642.7
PA10 INP In-position
range
Set an in-position range per command pulse.
1600
[pulse]
0 to
65535
Each
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......