4. STARTUP
4 - 7
The following explains the test operation select switch, the disabling control axis switches, auxiliary axis
number setting switches, and the axis selection rotary switch.
1
ON
2 3 4 5 6
1 2 3 4 5 6
ON
3-dight, 7-segment LED
Control axis setting switch
(SW2)
Axis selection rotary switch
(SW1)
Auxiliary axis number setting switch
For manufacturer setting
Control axis deactivation switch
Test operation select switch
MR-J4 2-axis servo amplifier
Auxiliary axis number setting switch
Control axis deactivation switch
Test operation select switch
MR-J4 3-axis servo amplifier
1
ON
2 3 4 5 6
(1) Test operation select switch (SW2-1)
To use the test operation mode, turn "ON (up)" the switch. Turning "ON (up)" the switch enables the test
operation mode for all axes. In the test operation mode, the functions such as JOG operation,
positioning operation, and machine analyzer are available with MR Configurator2. Before turning "ON
(up)" the test operation select switch, turn "OFF (down)" the disabling control axis switches.
Control axis deactivation switch
Set to the "OFF (down)" position.
Test operation select switch
Set to the "ON (up)" position.
Control axis deactivation switch
Set to the "OFF (down)" position.
Test operation select switch
Set to the "ON (up)" position.
1
ON
2 3 4 5 6
MR-J4 2-axis servo amplifier
MR-J4 3-axis servo amplifier
1
ON
2 3 4 5 6
(2) Disabling control axis switches (SW2-2, SW2-3, and SW2-4)
Turning "ON (up)" a disabling control axis switch disables the corresponding servo motor. The servo
motor will be disabled-axis status and will not be recognized by the controller. The following shows the
disabling control axis switches for each axis.
MR-J4 3-axis servo amplifier
1
ON
2 3 4 5 6
For manufacturer setting
Disabling control axis switch for B-axis
Disabling control axis switch for A-axis
Disabling control axis switch for C-axis
Disabling control axis switch for B-axis
Disabling control axis switch for A-axis
1
ON
2 3 4 5 6
MR-J4 2-axis servo amplifier
Disable the axis that you do not use. Set them from the last axis to the first axis in order. When only the
first axis is disabled, [AL. 11 Switch setting error] occurs. The following lists show the enabled axes that
the controller recognizes and the disabled axes that the controller do not recognize.
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......