13. USING STO FUNCTION
13 - 3
13.1.5 Specifications
(1) Specifications
Item Specifications
Functional safety
STO (IEC/EN 61800-5-2)
Safety performance
(Certification standards)
EN ISO 13849-1 category 3 PL d, IEC 61508 SIL 2,
EN 62061 SIL CL2, EN 61800-5-2 SIL 2
Mean time to dangerous failure
(MTTFd)
100 years or more (Note)
Diagnostic converge (DC)
Medium (90% to 99%) (Note)
Average probability of dangerous
failures per hour (PFH)
[1/h]
1.68 × 10
-10
Number of on/off times of STO
1,000,000 times
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
Note. This is the value required by safety standards.
(2) Function block diagram (STO function)
Base power
supply for
upper arm
Base power
supply for
lower arm
Shut-off signal (STO1)
CN8
Monitor signal (TOFB1)
Shut-off signal (STO2)
Monitor signal (TOFB2)
Shut-
off
Shut-
off
Servo motor
M
Power
module
(3) Operation sequence (STO function)
STO2
STO1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0 r/min
(8 ms)
Servo motor speed
EM2 (Forced stop 2)
Magnetic contactor
Base circuit
(Supplying energy to
the servo motor)
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......